Milton came ashore in October 2024 and the city called the flooding as bad as Ian two years before. Two residents died. The Tomoka and the Halifax came up into the same streets they had in 2022. For an air conditioning company, the storm itself is a few hours of silence: the power is out, the phones are busy with people who want to know what to do, and the answer is the same for everyone. Turn the system off at the thermostat and, if you can reach it safely, at the breaker. A system that tries to restart on a flickering grid, or on a flooded condenser, is a system that fails later.

What follows is the calendar we recommend for the twelve months after, the one we would hand any Ormond Beach owner the morning after the next storm.

The first 48 hours

Before the power comes back, or before you turn the breaker on:

  • Look at the outdoor unit for a water line. Note its height.
  • Look for anything that moved: a unit shifted on its pad, a disconnect box hanging, a line set pulled at the wall.
  • Lift the top grille if it comes off easily and look for debris against the fan. Milton’s winds packed oak leaves and palm fronds into cabinets across the city.
  • Check the air handler for water in the secondary pan or on the floor around it.
  • If any of those is wrong, leave the power off and call. If all are clean, restore power and let the system run while you watch and listen for the first fifteen minutes.
Technician removing storm debris packed inside an outdoor air conditioner after a hurricane
Day two. Before the power is back is the time to find what the wind put inside the cabinet, not after the fan has tried to turn through it.

The first week

The calls that week are for systems that would not start, that tripped breakers, or that started and smelled wrong. Dispatch triages houses with older or ill residents first, then no-cool calls, then the rest. A first-week inspection on a system that did get wet opens the control compartment, dries and tests the electrical side, rinses silt off the coil, cleans the pans and checks the drain. Where the water reached the compressor terminals or the control board, the conversation turns to replacement, and the replacement goes on a stand.

November

The cooling season is winding down, which is the gift of an October storm: there is time. November is for the deferred items: units re-secured with hurricane-code tie-downs, disconnects remounted higher, line-set insulation that the wind stripped replaced, and the first heat-pump heating checks before the cold nights start. Owners who ran on generators report the compressor would not start; this is when soft-start kits go on.

Call 866-266-5709

December and January

The quiet months, and the months for prevention. Replacements in the flood streets get stands set above the Milton line with margin. Air handlers in garages that flooded are raised on platforms. Surge protectors are added, because the grid’s restoration brought its own surges and the Daytona area’s lightning season is only a few months off. Heating runs on the coldest nights, and a system that took water in October sometimes shows it now as a failed defrost control or a strip that will not energize.

February and March

The first warm week arrives, and with it the late failures: capacitors that were weakened by water or surge in October and held through a mild winter let go on the first 85-degree afternoon. Coils that were rinsed in October but never properly cleaned show their restricted airflow as the load climbs. The spring maintenance visit is where the storm’s remaining damage is found, and it should be scheduled before the oaks drop their pollen, not after.

April through June

The summer load builds. Systems that passed every test so far are running full days, and the ones with a compromised compressor from October’s flood or surge begin to draw high current on hot afternoons. Breakers trip. This is the last window before hurricane season to replace a unit that has been limping since the storm, with the FPL instant rebate applied and a stand under it.

July and August

Peak season. Nothing on the calendar but running, and the maintenance that keeps a system running: filters, drain lines flushed before the September rains, condensate pumps checked. Any system that has made it this far without a storm-related failure is probably clear of one.

September and October

Hurricane season’s heart, and the anniversary. The pre-season check: tie-downs tight, disconnect sealed, line set protected, debris cleared from around the unit, the generator’s capacity confirmed against the compressor’s starting current, the float switch tested. The thermostat set a few degrees cooler the day before a storm so the house starts the outage cold. And the list from the first 48 hours, printed and on the refrigerator, for the next one.

What the first winter tends to show

Picture the pattern across Ormond Beach after a storm like Milton: the dramatic failures are few and early, and the quiet ones are many and late. An owner who gets an inspection in the first week, and a spring visit before the first heat, catches nearly all of theirs as parts. An owner who resets the breaker and moves on meets theirs in June. Cook’s answers the phone around the clock from the Palm Coast headquarters without an after-hours charge, in a storm year and in every other year.

After-the-storm questions

The power came back and the AC started. Why would I still have it inspected?

Because what fails after a storm fails late. Water in the control compartment, debris against the fan, a surge that weakened a control board: none of them stop a system on day one. An inspection in the first week finds them while they’re a part, not a compressor.

Is it safe to run the AC on a generator?

Only if the generator can carry the compressor’s starting current, which is several times its running draw. Many portable generators can’t. A soft-start kit on the compressor lowers that starting surge enough for a mid-size generator to manage, and it’s a good addition before the next season.

My outdoor unit shifted on its pad in the wind. Is that serious?

It can be. A unit that moved has stressed the refrigerant lines where they enter the cabinet, and a kinked or cracked line is a leak waiting for summer. Don’t run it until someone has checked the line set and re-secured the unit with code tie-downs.

What's the one thing to do before the next storm, based on last time?

Elevate what flooded and tie down what moved. Everything else on this calendar is recovery; those two are prevention, and the quiet months of winter are when they get done.